Code
Display text
Description
Range
Submenu
DHW blocking
active
Domestic hot water preparation
blocking is active
0 = No
1 = Yes
Gas fired appliance
Anti legionella act. Anti legionella is active
0 = Off
1 = On
Internal DHW
Tank DHW
Gas fired appliance
DHW active
Domestic hot water preparation
is active
0 = No
1 = Yes
Gas fired appliance
DHW Enabled
Domestic hot water preparation
is enabled
0 = No
1 = Yes
Gas fired appliance
CH Enabled
Central heating production is
enabled
0 = No
1 = Yes
Gas fired appliance
Struct loc DLS
PDO
Structure used to fill the location
and DLS PDO message.
Mandatory bus master
Ini status
give the device initialisation
status
0 = Not Done
1 = CheckObjPointerTable
2 = Default
3 = Read Configuration 1
4 = Read Configuration 2
5 = Read Custom Param.
6 = Finished
7 = Blocking Parameters
8 = PST Error
30 = WaitForConfiguration
System Functionality
HMI display info
Trending string containing all
relevant information for
diplaying appliance status on
the HMI MK2
System Functionality
Gas fired appliance
RTC update on
CAN
A Real Time Clock update has
been received on the CAN bus
0 = No
1 = Yes
Mandatory bus master
Total
EnergyConsu Y0
Total energy consumed in the
current year
0 kWh - 4294967294 kWh
Gas fired appliance
Auto filling active
Setting to enable or disable the
autofilling feature
0 = Standby
1 = Filling Needed
2 = Filling Active
3 = Auto filling pending
Auto filling CH
ChimneyModeStat
us
Status of the Chimney mode
0 = Off
1 = Low power
2 = Medium power
3 = High power
4 = Cooling
Gas fired appliance
AM001
DHW active
Is the appliance currently in
domestic hot water production
mode?
0 = Off
1 = On
Internal DHW
Tank DHW
Gas fired appliance
AM010
Pump speed
The current pump speed
0 % - 100 %
Internal DHW
Gas fired appliance
AM011
Service required? Is service currently required?
0 = No
1 = Yes
Gas fired appliance
AM012
Status Appliance
Current main status of the
appliance.
See
Status information
System Functionality
AM014
Sub status
Appliance
Current sub status of the
appliance.
See
Status information
System Functionality
AM015
Pump running?
Is the pump running?
0 = Inactive
1 = Active
Gas fired appliance
9 Settings
7717201 - v03 - 25062019
MID _HMI T-control - Gas 120 ACE
63