8 Operation
8.1
Definition of zone and activity
8.1.1
Zone
Term given to the different hydraulic circuits CIRCA, CIRCB, .... It
indicates several rooms served by the same circuit.
Tab.20 Example
Marker
Zone
Factory-set name
1
Zone 1
CIRCA
2
Zone 2
CIRCB
8.1.2
Activity
This term is used when programming time ranges. It refers to the client's
desired comfort level for different activities during the course of the day.
One set point temperature is associated to each activity. The last activity
of the day remains valid until the first activity of the following day.
Tab.21 Example:
Start
of the activity
Activity
Set point temperature
6:30
Morning
1
20 °C
9:00
Away
2
19 °C
17:00
Home
3
20 °C
20:00
Evening
4
22 °C
23:00
Sleep
5
16 °C
8.2
Switching the summer mode on or off
You can switch off the central heating function of the boiler to save energy,
for example during the summer period.
1. Select the tile [ ].
2. Press the button to confirm the selection.
3. Use the rotary knob to select Force summer mode.
4. Press the button to confirm the selection.
5. Use the rotary knob to select the following setting:
5.1. On to switch off the central heating function.
5.2. Off to switch the central heating function on again.
6. Press the button to confirm the selection.
8.3
Activating the holiday program
If you will be absent for several weeks, you can reduce the room
temperature and domestic hot water temperature in order to save energy.
To activate holiday mode for all zones including the domestic hot water:
Fig.52
1
MW-1001145-2
2
Fig.53
MW-1001144-2
°C
16
06:30
09:00
17:00
20:00
23:00
19
20
22
5
1
2
3
4
5
8 Operation
40
MID _HMI T-control - Gas 120 ACE
7717201 - v03 - 25062019