MWS_55_e.indb Page 93
Manual MWS 55 / MWS 88 / MWS 10 and Sensors 55
geändert am 04.12.2020 von DO
REINHARDT
System- und Messelectronic GmbH
Fax: 08196/7005 and 1414 email:
http://www.reinhardt-wetterstationen.de
!Kx,Cy<#13>
;Sensor position x (1..32) set sensor dependent calculation option y (0..15).
0 = Standard. See s
!Kx,P0..7<#13>
;Sensor position x (1..32), set precision.
Sets the number of decimal places (0..7).
With a value > 2 the sensor position (= alias) will be marked with a "P".
!Kx,MW0<#13>
;Sensor position x (1..32), attenuation averages with real values
!Kx,MW1<#13>
;Sensor position x (1..32), attenuation averages with attenuated values
!Kx,Gy.y<#13>
;Sensor position x (1..32), gain (= multiplier) of real value before limitation
!Kx,Ty.y<#13>
;Sensor position x (1..32), translation (= offset) of real value before limitation
!Kx,Uy.y<#13>
;Sensor position x (1..32), sets lower limit (not concerning the raw value)
!Kx,Oy.y<#13>
;Sensor position x (1..32), sets upper limit (not concerning the raw value)
!Kx,OZ0<#13>
;Sensor position x (1..32), normal linitation
value > upper limit: value = upper limit
value < lower limit: value = lower limit
!Kx,OZ1<#13>
;Sensor position x (1..32), establish circular reference of limitation.
Falling limitated value = value + (upper limit - lower limit) :
...UG+1->UG->OG->OG-1...
Rising limitated value = value - (upper limit - lower limit) :
...OG-1->OG->UG->UG+1...
Caution! Circular reference has got effects onto the average calculation!
(see wind average)
!Kx,SMy.y<#13>
;Sensor position x (1..32), averaging coefficient for average
(for additional weaken / enhance of averaging)
!Kx,ZSy<#13>
;Sensor position x (1..32), set interval for sensor in seconds
(Average, clear min / max)
!Kx,ZDy<#13>
;Sensor position x (1..32), interval in *2 seconds
!Kx,Zy<#13>
;Sensor position x (1..32), interval in *10 seconds
!Kx,SW0<#13>
;Sensor position x (1..32), use real values for entire statistics
(min/max/average/standard deviation)
!Kx,SW1<#13>
;Sensor position x (1..32), use attenuated values for entire statistics
(min/max/average/standard deviation)
!Kx,RA1<#13>
;Sensor position x (1..32), automatic reset of statistic values
(counter = interval)
!Kx,RA0<#13>
;Sensor position x (1..32), auto reset off
(counter counts up to interval then remains on value)
!Kx,RP0|1<#13>
;Sensor position x (1..32), reset of statistic values on command !P, or rather
disable / enable storing into data logger
!Kx,RR0|1<#13>
;Sensor position x (1..32), reset of statistic values on command !R, or rather
disable / enable global hour of reset