Read sensor configuration of internal sensors:
[since V3.0200]
?Ix<#13>
e.g. ?I2 (Wind speed)
===== Internal: 02 =====
>Sensor 58:
|->Mode: Timer
|->Gain: 1.0000
|->Transl.: 0.0000
e.g. ?I3 (Rain counter)
===== Internal: 03 =====
>Sensor 59:
|->Mode: Counter (/ + \)
|->Reset: (none)
e.g. ?I4 (Counter/Timer/Analogue)
===== Internal: 04 =====
>Sensor 60:
|->Mode: Analog
Read Linearisation table x (1..32), e.g. ?L1 (Temperature)
?Lx<#13>
Alias x (= Sensor position x) (1..32) read values, e.g. ?K2 (Temperature):
?Kx<#13>
===== 02:TE =====
>Name: Temperature, Unit: °F (1.810000, 32.000000)
>Value:
|->Real: 26.5311
|->Smooth: 26.5231
|->Raw: 27368.0000
>Statistic:
|->Min: 26.4239 @ 01:58:56, 01.01.(001)
|->Average: 26.4819
|->Max: 26.5740 @ 01:59:05, 01.01.(001)
|->Std.Dev.: 0.0307
|->Interval: 126 (300)