8.5 Plain text commands
Plain text commands are used for moblie connections via SMS but also can be used via serial
connection (USB, RS-232) or Ethernet tunnel by adding a * in front of the commands
8.5.1 Listing of plain text commands
DATA
[<output> <on/off>,<output> <on/off>, …]
*DATA
[<output> <on/off>,<output> <on/off>, …]
This is used to display or switch the digital outputs. To turn one or more outputs on or off, the
command must be followed by the output designation (e.g., O1 or sensor prefix or name) and the
desired state. This can either be a numeric one, or the word ON, or numeric zero, or the word
OFF. Further outputs must be separated by spaces or commas.
To operate the outputs manually, this function must be enabled (see
ADMIN SET PERMIT
).
Whether with or without output switch, the DATA command always returns the current states
of the outputs,e.g.
DATA O1 on O2 off o3 1,o4 0
leads to output:
DATA
Reinhardt MWS
>OUTPUT 1: ON
>OUTPUT 2: OFF
>OUTPUT 3: ON
>OUTPUT 4: OFF
>OUTPUT 5: OFF
>Heating_1: OFF
>Heating_2: OFF
>Fan: ON
With defined (or in sensor output contained sensors) sensors, the sensor name (or sensor prefix)
is used instead of OUTPUT.
It also is allowed to send
DATA fan on
.
Caution:
You may temporarily override an automatic circuit (such as Fan) set before with ADMIN SET
OUTPUT x TERM with this command. This should be avoided as far as possible, or be used only
in the switching breaks / inactive phases of the automatic, otherwise the automatic switches
within a second again.
LEVEL
*LEVEL
Returns the current supply voltage (in volts) aus, i.e.
VOLTAGE LEVEL
>17.94
ADMIN STATION IDENT x
*ADMIN STATION IDENT x
sets the device address 0<= x <= 255. with x = 255 the device accepts all commands.
Only when used with RS-485 protocol(s).