ADMIN LOCK
*ADMIN LOCK
sets the Flash write protection. No changes in the configuration data are saved anymore (corresponds
to the command! S + 8 via the serial interface). Even the administrator can not make any changes
until the flash was unlocked with ADMIN UNLOCK (or! S-8), (change number / password, etc.).
ADMIN UNLOCK
*ADMIN UNLOCK
disables the flash write protection. Now changes can be made in the configuration data.
This corresponds to the! S-8 command via the serial interface.
ADMIN OFF
*ADMIN OFF
switches off the station in battery mode (and standard mode).
ADMIN SAVE CONFIG
*ADMIN SAVE CONFIG
Saves all current settings in the text file /_system/save/config.sav on the SD card. An existing
config.sav file is saved under the name config.bak in the same directory.
ADMIN LOAD CONFIG
*ADMIN LOAD CONFIG
Loads the file /_system/save/config.sav and transferres the containing information into the flash
memory. This takes about 20 minutes. If the command was sent via the serial interface, a progress
bar is transmitted:
LOAD CONFIG |---------+---------+---------+---------+---------I---------+---------+---------+---------+---------|
Each minus sign corresponds to 1%, each plus sign to 10% and the "I" to 50%.
ATTENTION! If the flash memory is write-protected (ADMIN LOCK), the command will be execu-
ted, but no data will be changed!
Accordingly, the command can only be used meaningfully
with either unlocked flash or in SECURE mode.
ADMIN POWER REMOVE
[ab V3.0242]
*ADMIN POWER REMOVE
Disables the backup battery. The next time the station is staked off, the real-time clock loses the
data, i. the time starts at the following power up at 0 o'clock on 01.01.2000. New data will not be
stored correctly until the time is set correctly again!
ATTENTION! Only supported from board version 1.057!
ADMIN POWER MOUNT
[ab V3.0242]
*ADMIN POWER MOUNT
Activates the backup battery (again) to the controller. This is performed automatically each time
the station is powered, but this can be used to undo an inadvertent ADMIN POWER REMOVE
command.
ATTENTION! Only supported from board version 1.057!