30
Cooling settings
With the ON/OFF button, cooling can be switched on by the
user and the desired room temperature can be set
(corresponding to the comfort temperature for heating).
Transition cooling
means that cooling is only active if the
outdoor temperature exceeds the set limit (Transition outdoor
temp.).
This option may not always be available!
To activate the heat pump in cooling mode, it is necessary to turn on the option of
cooling from the heat pump in the heat pump menu.
4.3.2. ThSt zone
Zone of thermal store heating to a preset temperature following a time program. The zone can
be switched on/off by the user with the
ON/OFF
button.
This function is mainly used when there is an increased heat demand outside the heating
season or to accumulate more heat than is needed for heated rooms. A good example could
be a swimming pool in combination with underfloor heating.
In the menu of this zone it is possible to set the comfort and setback temperature for the
required thermal store temperature. The actual desired thermal store temperature is then
calculated as the maximum of the requirements from the ThSt zone and active heating zones.
The time program setting is identical to the time program setting in zones 1 - 6.
4.3.3. Pool heating
The pool heating function is only available if enabled in the service level!
Pool heating to adjustable desired temperature. The heating can be switched on or off by the
user with the
ON/OFF
button.
4.3.4. Holidays
The Holiday function is intended for background heating of the building during a longer
absence. The Holiday function can be switched on or off with the
ON/OFF
button.
After turning on the Holidays, it is important to set the start and end time and date of the
holidays function. For each heating zone and DHW heating the temperature can be set this
zone will be heated to during the holidays.
If the heated space is divided into several zones, the ON/OFF buttons can be used to
determine whether the holiday function will be activated for the whole or for the individual zones
only. If DHW circulation or HRV zone is connected, you can use the ON/OFF button to select