Operation & Maintenance w/IPB
G2 Series Decontamination Water Heater
0014
Part Number: 1006375
0014-10
DHS Systems LLC
This document contains information proprietary to DHS Systems LLC and is intended solely for use by its customers. No portion of this document may be reproduced
for release to a third party without written consent of DHS Systems LLC.
INSTALLATION OF FLEXIBLE COUPLING;
2. Install the fuel pump/solenoid as follows:
a. Slide the flexible coupling onto the fuel pump/solenoid shaft.
b. Install fuel pump/solenoid assembly into burner motor housing.
c. Loosely thread (2) mount bolts into the fuel pump housing; do not tighten at this time.
d. Using a 7/16” open end wrench, connect and tighten the fuel nozzle tube B-nut.
e. Using a 9/16” open end wrench, connect and tighten the fuel line B-nut at the fuel pump.
f.
Using a ½” open end wrench, tighten the (2) fuel pump mounting bolts.
g. Using a 9/16” open end wrench, connect and tighten the fuel in-line at the fuel water strainer housing.
h. Connect the solenoid electrical plug.
i.
Reconnect power cord to power supply outlet.
j.
Perform ops and leak checks.
END OF TASK