Operation & Maintenance w/IPB
G2 Series Decontamination Water Heater
0014
Part Number: 1006375
0014-12
DHS Systems LLC
This document contains information proprietary to DHS Systems LLC and is intended solely for use by its customers. No portion of this document may be reproduced
for release to a third party without written consent of DHS Systems LLC.
INSTALLATION OF THE ELECTRONIC IGNITER ASSEMBLY (CONT):
h. Reinstall the electronic igniter and base plate assembly; ensure the igniter springs are contacting the
electrodes tangs and electrical wires are not pinched.
i.
Using a 5/16” open end wrench, install and tighten (2) hex head screws.
j.
Using a cross-point screwdriver, install and tighten (2) cross-point screws.
k. Reconnect power cord into power supply.
l. Perform
operations
check.
END OF TASK