OPERATOR INSTRUCTIONS
G2 SERIES DECONTAMINATION WATER HEATER
FLUSHING THE SYSTEM PROCEDURES
GENERAL
This Work Package details the procedures for Flushing the System before start-up procedures of the G2 Series
Decontamination Water Heater.
FLUSHING THE SYSTEM
To ensure minimal problems and optimal performance of the G2 Series Decontamination Water Heater, please read
this manual carefully and follow all procedures. Failure to observe these procedures could result in serious injury or
water heater damages.
CAUTION
Risk of Water Heater Damage
Be certain that the discharge hoses are not connected to the water heater
while flushing the system. Flushing allows minerals deposits to be released
which would obstruct or damage the hoses.
This unit has a steel coil which, after setting, will cause the water remaining in the coil from the previous usage to turn
brown or black. This water
must be
flushed from the system before start-up. This procedure should be performed
without
any of the discharge hoses attached.
1. Connect the supply hose to water supply source.
2. Turn water supply source ON and flush the supply hose then turn water OFF.
3. Connect other end of supply hose to the water heaters’ water source inlet.
4. Turn the water supply source ON.
5. Turn the temperature control valve counter clockwise (CCW) until water begins to flow. This allows the unit to
flush any particles from the system. The unit is flushed when the water is clear.
6. Once the system has been flushed, turn the temperature control valve clockwise (CW) to stop the water flow.
7. Connect the discharge hoses to the water heater outlets.
END OF TASK