CAUTION
The items listed in the following table must be performed after each use for the
G2-I and G2S-I Decontamination Water Heater ONLY.
Table 2. Operator Functional Services.
ITEM
NO.
INTERVAL
ITEM TO BE
CHECKED
OR SERVICED
PROCEDURE
EQUIPMENT NOT
READY/
AVAILABLE IF:
G2-I / G2S-I
ONLY
1
AFTER
Clean Injector
Rinse injector after each uses.
If Decon solution
remains in injector,
injector may dry out
and damage lower
end.
2
AFTER
Clean Suction
Tube Filter
Screen
Remove filter screen from suction tube and
clean by washing in fresh water.
If filter screen is
damaged or
clogged.
3
AFTER
Clean Decon
Solution Tank
Rinse Decon solution tank thoroughly after
each use to prevent any contaminates from
entering tank
If Decon solution
tank becomes
contaminated.
4
AFTER
Clean Inlet
Filter
Clean or replace inlet filter as required to
increase life of water heater.
If inlet filter is dirty
and water heater
has decreased
pressure.
END OF WORK PACKAGE