DECON SOLUTION INJECTOR OPERATION (CONT)
CHANGING FEED RATE
The feed rate on the injector is adjustable, even while operating and under pressure. Rotate the Ratio Adjustment
Sleeve, clockwise (CW) to decrease and counter-clockwise (CCW) to increase (see Figure 1), to change the Decon
solution ratio. The setting indicator mark indicates the approximate ratio of injection setting. Check the Decon
discharge outlet to assure desired feed rate is being delivered.
NOTE
Do not rotate the Ratio Adjustment Sleeve below the lowest setting line on
decal. This can cause the injector to lock.
Ratio Adjusting Sleeve
Figure 1. Ratio Adjustment Sleeve and Bypass Lever.
END OF TASK