![Redline Communications AN-30e User Manual Download Page 84](http://html.mh-extra.com/html/redline-communications/an-30e/an-30e_user-manual_1429370084.webp)
AN-30e
user manual
70-00035-01
Proprietary Redline Communications © 2004
November
16,
2004
Page 84 of 103
8.4 CLI
Interface
8.4.1 Console (RS-232) Port
All operator communications with the terminal may be made using a direct
connection to the serial Console Port on the back of the terminal. This section
describes the procedures for configuring and operating the terminal via the Console
Port using the command line interface (CLI).
Connect a PC/Terminal to the terminal serial port DB9 connector using a cross-
connect or null modem cable (DB9 female-female). Set the PC/Terminal to emulate a
VT-52 or VT-100 terminal, using the following port settings: Bits Per Second: 9600;
Data Bits: 8; Parity: None; Stop Bits: 1; Flow Control: Hardware
The following table lists the terminal 9 PIN D-SUB male connector pinout.
Table 40: Console (RS-232) Port Pinout
Pin
Name
RS232
V.24
Description
1 CD CF 109
Carrier
Detect
2 RXD BB 104
Receive
Data
3 TXD BA 103
Transmit
Data
4
DTR
CD
108.2
Data terminal Ready
5 GND AB 102
System
Ground
6
DSR
CC
107
Data Set Ready
7
RTS
CA
105
Request to Send
8
CTS
CB
106
Clear to Send
9 RI CE 125
Ring
Indicator
V.24 column is ITU-TSS V.24 circuit name.
RS232 column is RS232 circuit name.