Table 35: AN-30e Technical Specifications
Duplex Technique:
Dynamic TDD (time division duplex)
Wireless Transmission:
OFDM (orthogonal frequency division multiplexing)
Network Connections:
E1 transport: framed and unframed, full and fractional
(RJ-48c), 10/100 Ethernet (RJ-45)
System Configuration:
HTTP (Web) interface, SNMP, CLI via Telnet/console
Network Management:
SNMP: standard and proprietary MIBs, Full
management by RedAccess NMS
Power Requirements:
Single/dual auto-sensing 110/220/240 VAC 50/60 Hz,
Single/dual 18 VDC to 72 VDC, 49 W maximum,
Redundant Power:
Optional dual AC or dual DC power supply (dual cord)
with automatic fail-over
Compliance:
EN 60950, EN 301 893, EN 301 390, EN 301 489-1 &
17, FCC part 15
Operating Temperature:
IDU Operating Cond.: 5 C to 40 C,
IDU Short-Term Cond.: -5 C to 55 C for up to 16 hours
ODU Operating Cond.: -40 C to 60 C
Dimensions:
IDU: 431.8 mm x 304.8 mm x 44.45 mm (17" x 12" x
1.75")
Weight:
2.5 Kg (5.5 lb)
TDM Specifications:
Clocking: Adaptive/loopback/internal
Diagnostics:
Remote loop and local loop testing, detects and
generates LOS, AIS and RAI
Interface Ports:
One to eight TDM ports, supports Fractional nx64
Services
Jitter Buffering:
5-300 milliseconds
Round Trip Delay (RTD):
Less than ten milliseconds
Line Length:
2000 m using 22 AWG twisted pair cable
E1 Interfaces:
Connector: RJ-48c
Data Rate:
2.048 Mbps
Framing:
Unframed, CRC4, FAS/MFAS
Jitter: ITU-T
G.823
Line Code:
HDB3, AMI
Line Impedance:
Balanced 120 Ohm
Line Protection:
ITU-T K-20, K-21
Standards:
ETS TBR 12/13, ITU-T Rec., G.703, G.704, G.706,
G.732, G.821, G.826
T1 Interfaces
Connector: Balanced
RJ-48c
Data Rate:
1.544 Mbps
Framing:
Unframed, D4 (SF), ESF
Jitter:
AT&T TR-62411, ITU-T G.824
Line Build-out:
0 dB, -7.5 dB, -15 dB, –22.5 dB