AN-30e
user manual
70-00035-01
Proprietary Redline Communications © 2004
November
16,
2004
Page 27 of 103
Fault LED
The Fault LED lights solid red to indicate a serious problem with the system software
or hardware.
Check the IF cable for loose connections. Also, refer to the System Logs screen and
RF Status codes for additional information about the problem. Alternatively, if a
short-reset or long-reset does not resolve the problem, contact your local
representative.
Sync LED
The Sync LED lights solid green when the AN-30e is synchronized with an external
clock. The Sync port is currently disabled, and is enabled in a future software release.
Reset Switch
The reset button is recessed in the front panel of the terminal. To operate the switch,
use a small narrow object (i.e., paper clip) to depress the switch.
Depressing the reset button for less than five seconds activates a short-reset
(equivalent to cycling power on the terminal). Depressing the reset button for longer
than five seconds activates a long-reset and some parameters are changed to the
factory default settings. Refer to the following table for details.
Table 9: Front Panel Reset Switch
Operation Result
Depress
switch less
than 5
seconds.
Statistical values are reset.
A short reset may also be activated remotely from the
Web maintenance tool by clicking on the System Reset
button at the bottom of the System Configuration screen.
Depress
switch
longer than
5 seconds.
Reload the factory default configuration for the following
settings: IP Address, IP Subnet Mask, Channel, System
Name, Username, and Password.
Refer to section 69: Factory Default Settings on page 69.
4.3.7 The TDM Interface
The TDM interface includes TDM ports to connect the terminal to a PBX or other
TDM device. Each port has Alarm and Sync indicator LEDs.
TDM Ports
The TDM interface is equipped with eight RJ-48 ports. Entering the product options
key selects the number of active ports. The following table lists the pinout for the
TDM interface.
Table 10: TDM Port RJ-48 Pinout
Jack Pin
Function
1
Rx Data (R1)
2
Rx Data (T1)
4
Tx Data (R2)
5
Tx Data (T2)