Peristaltic Pump ISI Series
The shims are fitted in the factory. The number of shims can be adapted
to the actual operating conditions according to the following tables.
Slight variations in colour of polyurethane rollers is normal.
8.4.1 Model ISI 10
Hose materials – NR, NBR, EPDM, CSM, NR-A and NBR-A:
Number of shims of 0.5 mm thickness (part number AX102.01.49).
NOTE:
for fluid temperatures > 60 ºC: reduce shim quantities by 1.
Bar
Revolutions/minute
0-19
20-39
40-59
60-79
80-99
0.5
1
1
1
1
1
Number of
shims
2.0
1
1
1
1
1
4.0*
2
1
1
1
1
6.0
2
2
2
N/A
N/A
8.0
3
2
N/A
N/A
N/A
*Factory default setting if working pressure is not specified. N/A: Outside standard opera-
ting range of pump.
Hose materials – NORPRENE / SILICONE:
One 2.5 mm shim can be used (part number AX102.01.16), alternatively five 0.5 mm
shims can be used (part number AX102.01.49) for a total of 2.5 mm.
NOTE:
for fluid temperatures > 60 ºC: reduce shim quantities by 1.
Bar
Revolutions/minute
0-19
20-39
40-59
60-79
80-99
0.5
1
1
1
1
1
Number of shims
2.0
1
1
1
1
1
*Factory default setting if working pressure is not specified. N/A: Outside standard opera-
ting range of pump.
Summary of Contents for ISI 10
Page 1: ...Operating instructions ISI Series Peristaltic pump ALL THE HOSE PUMP YOU LL EVER NEED ...
Page 38: ...38 Operating instructions Peristaltic Pump ISI Series 11 3 Spare parts exploded ISI 13 Model ...
Page 42: ...42 Operating instructions Peristaltic Pump ISI Series 11 5 Spare parts exploded ISI 16 Model ...
Page 48: ...48 Operating instructions Peristaltic Pump ISI Series 11 8 Spare parts exploded ISI 22 Model ...
Page 53: ...53 13 Declaration of Conformity ...
Page 59: ......
Page 60: ...AHQ IOM EN 0849 1120 www realaxpumps com ALL THE HOSE PUMP YOU LL EVER NEED ...