13
Operating instructions
Peristaltic Pump ISI Series
5
CONSTRUCTION
The pump housing is closed off with a bolted front cover in order to avoid
the risk of injury.
The motor serves to drive the rotor. Two rollers attached to the rotor
serve to press the pump hose against the pump housing.
The rotary movement of the rotor alternately presses and releases the
rollers against the pump hose. This serves to suck the media and convey it
into the metering line.
Fig. 1: Diagram of functional principle
1. Pump housing | 2. Rotor| 3. Rollers | 4. Hose
4.3 Identification of the gearbox (b)
The gearbox has an identity plate with the model, serial number and
manufacturer’s details as well as information relevant to its’ function such
as reduction ratio.
4.4 Identification of the electric motor (C)
The motor has an identity plate with the model, serial number and
manufacturer’s details as well as information relevant to its’ function such
as electric power.