26
Operating instructions
Peristaltic Pump ISI Series
DESCRIPTION
UNITS
ISI 10 / 13
ISI 16
ISI 19
ISI 22
A
Roller
support bolts
Nm
7
M5
8 mm
Spanner
18
M8
13 mm
Spanner
18
M8
13 mm
Spanner
B
Cover bolts
Nm
Manual,
no bolts
Manual,
no bolts
Manual,
no bolts
C
Hose clamp
Nm
1
M6
10 mm
Spanner
2
M8
13 mm
Spanner
2
M8
13 mm
Spanner
D
Flange
bracket bolts
Nm
2
M6
Allen Key,
Size 5
4
M8
Allen Key,
Size 6
4
M8
Allen Key,
Size 6
E
Drive shaft
bolts
Nm
33
M6
Allen Key,
Size 5
33
M6
Allen Key,
Size 5
43
M10
17 mm
Spanner
9.3 Lubrication and cooling
ISI Pumps only require a thin film of grease to reduce the friction between
the roller and the outer surface of the Hose or Tube. No other lubrication
is necessary.
Lubricant quantity table
UNIT
ISI 10 / 13
ISI 16
ISI 19
ISI 22
Lubricant
–
realax
realax
realax
realax
Required
quantity
gram
50 – 70
100
ounce
1.8 – 2.5
3.5
Summary of Contents for ISI 10
Page 1: ...Operating instructions ISI Series Peristaltic pump ALL THE HOSE PUMP YOU LL EVER NEED ...
Page 38: ...38 Operating instructions Peristaltic Pump ISI Series 11 3 Spare parts exploded ISI 13 Model ...
Page 42: ...42 Operating instructions Peristaltic Pump ISI Series 11 5 Spare parts exploded ISI 16 Model ...
Page 48: ...48 Operating instructions Peristaltic Pump ISI Series 11 8 Spare parts exploded ISI 22 Model ...
Page 53: ...53 13 Declaration of Conformity ...
Page 59: ......
Page 60: ...AHQ IOM EN 0849 1120 www realaxpumps com ALL THE HOSE PUMP YOU LL EVER NEED ...