16
Operating instructions
Peristaltic Pump ISI Series
8
ASSEMbLY, COMISSIONING AND INSTALLATION
8.1
Ambient conditions
Assembly is to be carried out in the following order.
If the pump has to be installed outdoors, then it is to be equipped with
protection against sunlight and weather influences.
When positioning the pump, ensure that sufficient room for access is
provided for all types of maintenance work.
Limit values for hose temperature and pressure
Hose Material
Min. Temp.
(ºC)
Feed liquid
Max. Temp
(ºC)
Feed liquid
Min. Temp
(ºC)
Environment
Max. Pressure
(bar)
NR, NBR, EPDM, CSM,
NBR-A, NR-A
-10
80*
-20
8
Tube Material
Min. Temp.
(°C)
Feed chemical
Max. Temp
(°C)
Feed chemical
Min. Temp
(°C)
Environment
Max. Pressure
(bar)
NORPRENE, SILICONE
-10
90*
-20
2
TYGON
(only ISI 19)
70*
* At max. temperature., the life of hose is drastically reduced. Please contact authorized distributor for
applications in temperature range higher than 60
o
C.
8.2 Commissioning
8.2.1 Testing prior to commissioning the pump
The following tests are to be carried out:
- Check that the rollers are correctly fitted and fastened.
- Check that the drive and the Pump Housing are properly
lubricated. The specially formulated lubricant can be obtained
from the authorized distributor.
- Only switch the pump on if the front cover has been properly
attached.
- Check that the mains voltage is suitable for the motor.
- Check that the thermal overload protection (not included in
the delivery scope) corresponds to the value specified on the
motor type plate.
Summary of Contents for ISI 10
Page 1: ...Operating instructions ISI Series Peristaltic pump ALL THE HOSE PUMP YOU LL EVER NEED ...
Page 38: ...38 Operating instructions Peristaltic Pump ISI Series 11 3 Spare parts exploded ISI 13 Model ...
Page 42: ...42 Operating instructions Peristaltic Pump ISI Series 11 5 Spare parts exploded ISI 16 Model ...
Page 48: ...48 Operating instructions Peristaltic Pump ISI Series 11 8 Spare parts exploded ISI 22 Model ...
Page 53: ...53 13 Declaration of Conformity ...
Page 59: ......
Page 60: ...AHQ IOM EN 0849 1120 www realaxpumps com ALL THE HOSE PUMP YOU LL EVER NEED ...