Peristaltic Pump ISI Series
PROBLEM
POSSIBLE CAUSE
SOLUTION
Short
operational
lifetime of
the hoses
Chemical exposure
Check the compatibility of the hose with
the liquid being conveyed, the cleaning
fluid and the lubricant
High pump speed
Reduce pump speed
High conveying temperature
Reduce product temperature
High operating pressure
Reduce operating pressure
Pump cavitation
Check the suction conditions
Abnormal elevation of
temperature
Check number of shims
Unsuitable lubricant
Use realax lubricant
Insufficient quantity of grease
Reapply lubricant
Pump hose
pulled into
the pump
housing
High inlet pressure (> 3 bar)
Reduce inlet pressure
Pump hose filled with deposits
Clean or replace the pump hose
Holder (press connection)
insufficiently tightened
Re-tighten holder (press connection)
Insufficient grease
Reapply lubricant
The pump
does not
start up
Insufficient motor
performance
Check motor and replace if necessary
Insufficient output from
frequency converter
The frequency converter must match
the motor
Blockage in the pump
Check voltage. Start occurs at minimum
10 Hz
Check if the suction or discharge side is
blocked. Rectify blockage
Summary of Contents for ISI 10
Page 1: ...Operating instructions ISI Series Peristaltic pump ALL THE HOSE PUMP YOU LL EVER NEED ...
Page 38: ...38 Operating instructions Peristaltic Pump ISI Series 11 3 Spare parts exploded ISI 13 Model ...
Page 42: ...42 Operating instructions Peristaltic Pump ISI Series 11 5 Spare parts exploded ISI 16 Model ...
Page 48: ...48 Operating instructions Peristaltic Pump ISI Series 11 8 Spare parts exploded ISI 22 Model ...
Page 53: ...53 13 Declaration of Conformity ...
Page 59: ......
Page 60: ...AHQ IOM EN 0849 1120 www realaxpumps com ALL THE HOSE PUMP YOU LL EVER NEED ...