32
Operating instructions
Peristaltic Pump ISI Series
10 TROUbLESHOOTING
PROBLEM
POSSIBLE CAUSE
SOLUTION
Increased
pump
temperature
Pump hose has no lubricant
Lubricate pump hose
Increased product temperature
Reduce product temperature
Insufficient or poor suction
conditions
Check suction line condition
Pump speed too high
Reduce pump speed
Reduced flow
or pressure
Valves on discharge and or
suction side completely or
partially closed
Open valves
Pump hose insufficiently
compressed
Check number of shims
Pump hose rupture (the product
leaks out into the housing)
Exchange pump hose and clean
pump
Partial blockage of the suction
line
Clean pipe
Insufficient product quantity in
storage container
Fill storage container or exchange
pump
Insufficient diameter on the
suction side
Increase the diameter on the
suction side, as far as possible
Suction line too long
Shorten the suction line, as far as
possible
High viscosity of medium
Reduce viscosity, as far as possible
Air introduction in the suction
connections
Check connections and
accessories for air tightness
High pulsation on suction
Tighten connections and
accessories Mount anti-pulsation
equipment Reconsider application
(speed, etc.)
Vibrations on
pumps and
pipelines
The pipes are not correctly
fastened
Fasten pipes correctly (e.g. wall
brackets)
Pump speed too high
Reduce pump speed
Insufficient nominal width of the
pipes
Increase nominal width
Pump base plate loose
Fasten base plate
Pulsation dampers insufficient or
missing
Install pulsation dampers on
suction and / or discharge side
Summary of Contents for ISI 10
Page 1: ...Operating instructions ISI Series Peristaltic pump ALL THE HOSE PUMP YOU LL EVER NEED ...
Page 38: ...38 Operating instructions Peristaltic Pump ISI Series 11 3 Spare parts exploded ISI 13 Model ...
Page 42: ...42 Operating instructions Peristaltic Pump ISI Series 11 5 Spare parts exploded ISI 16 Model ...
Page 48: ...48 Operating instructions Peristaltic Pump ISI Series 11 8 Spare parts exploded ISI 22 Model ...
Page 53: ...53 13 Declaration of Conformity ...
Page 59: ......
Page 60: ...AHQ IOM EN 0849 1120 www realaxpumps com ALL THE HOSE PUMP YOU LL EVER NEED ...