Cyclone RazorOptimal User Manual
10 |
P a g e
Technical Services, Inc.
Infeed/Outfeed Tables
The Cyclone RazorOptimal comes with table attachment brackets for mounting the infeed and outfeed
tables. Use the diagram below to first bolt the table attachment bracket to the saw and then attach the
table. After attaching the tables to the saw make sure to level them. There are leveling adjustment bolts
on the table legs and also on the table attachment brackets shown below.
Electrical Power Connection
WARNING
The operator must remove from and lock out
all power sources to saw before servicing or
connecting power.
The saw has been factory wired to the requested voltage before shipment. The saw power requirements
are either
208 / 230 VAC 3φ 30Amps
OR
480 VAC 3φ 20Amps
. The RazorGage tower requires a
separate
120V 1φ
10A supply
. Check that your supply lines match the labeled voltage and the circuit
protection and wire gauge is adequate. Connect wires to the disconnect inside the electrical enclosure
as shown in pictures below.