Chapter 2: Commissioning Procedures
29
Setting water temperature
Set the correct water temperature as follows:
1. With the
Transducers Found
menu displayed,
scroll to the
Speed
option.
2. Press
OK
to display the
Speed
transducer setup
menu.
3. Scroll to the
Temperature Offset
option.
4. Press
OK
to display the
Temperature Offset
setup page.
5. Using a suitable thermometer, measure the
water temperature, then scroll to set the correct
system temperature value.
6. Press
OK
to accept the value and return to the
Speed
transducer menu.
7. Press
CANCEL
to return to the
Transducers
found
menu.
8. Press
CANCEL
to return to the
Search Results
summary.
9. Press
CANCEL
to return to the
Transducer Setup
start page.
10. Press
CANCEL
to return to the
Advanced Options
menu.
Calibrating smart transducers
WARNING: Ensure you use the correct depth offset
The use of the correct depth offset is critical to the safety of the
vessel. If an incorrect offset value is applied, this could result in misleading
depth information being displayed with a consequent risk of running
aground. Take great care to ensure you set the correct value.
Use this procedure to calibrate Depth & Temperature values for a smart transducer:
1. With the
Transducers found
menu displayed,
select
DST
or
DT
to display the
Details
page.
2. Press
OK
, to display the
Depth Offset
setup
page.
3. Check the type and value of the offset currently
applied:
•
If the offset type is what you require and the
value is correct for your boat, proceed from
step 7.
•
Otherwise proceed from step 4.
i
D1
1
177-1
Transducers found
Speed
Raymarine
Serial no.165321
Press OK to select
i
D
111
7
9
-1
Press OK to accept
Temperature Offset
7
Adjust temperature until it reads
actual sea temperaure
C
°
D1
1335-1
Press OK to select
Details
Transducer
Model No.
Serial No.
Software
Hardware
Voltage
Manufacturer
DST
DST800
11.8 V
Airmar
85024_1.book Page 29 Tuesday, January 27, 2009 11:31 AM