P/N 016-0235-001 Rev. B
35
SETTINGS
FIGURE 20. Center Rack Rotation
AUTOBOOM FOLD CALIBRATION
The AutoBoom Fold Calibration allows the user to update the primary boom fold (Yaw) sensor calibration. These
sensors are used to prevent the Master Switch from being turned on if the booms are not unfolded.
1. Fold the boom in so the booms are stored in the transport position.
2. Touch the Next button to continue fold calibration.
FIGURE 21. AutoBoom Fold Setup- Fold Boom In
NOTE:
Most machines will skip to step 9. If your screen does not match that shown in Figure 22 on page 36,
proceed to step 9.
3. Unfold the booms and lower the center rack.
4. Touch the Next button to continue the fold calibration.