P/N 016-0235-001 Rev. B
37
SETTINGS
FIGURE 24. Vertical Center Sensor Calibration - Operation Zone
NOTE:
For RoGator, this is low enough that the center rack is able to rotate freely without hitting the travel
stops. This is typically about 4 in. [10 cm].
8. Touch the Next button to continue the fold calibration.
9. Lower the center rack to a typical operating position and unfold the booms.
10. Touch the Next button to complete the fold calibration.
FIGURE 25. Vertical Center Sensor Calibration - Set to Spray Position
AUTO CALIBRATION
AutoBoom XRT has a library of calibrated values that are automatically used when the system is initially
configured. These values have been found to be good defaults specific to your Make, Model, and Boom Width.
For optimal performance, some of these values should be customized to your specific machine. This helps
account for differences in hydraulic system performance, oil viscosity, and other characteristics that vary between
machines. This can be performed automatically using the Auto Calibration feature.