28.Press Next.
NOTE:
Note: Machines that use an IMU (Inertial Measurement Unit) for Center Rotation Measurement will
perform step 29 through step 34. Machines that use a rotary position sensor will skip to step 35.
29.Verify the ECU Orientation on the machine matches the image on the ECU orientation page. If needed, press
the rotate buttons on the right side of the tab to adjust the orientation.
FIGURE 11. IMU Orientation
30.If required, press the Location button to rotate the machine view on the ECU Orientation screen.
31. Press Next.
32.Verify the machine is parked on a level surface