AXIS-H EMC/AXIS-H EMC+W
Check: Pressure sensor
RAUCH Landmaschinenfabrik GmbH D-76547 Sinzheim
Customer service hotline: +49 (0)7221 985 250
E-mail: [email protected]
Page
2
of
3
29.10.2014
Chapter 670
1. Measurement:
Constant current: Hydraulic control unit off
Load Sensing: Tractor off
In idle state, the AD values have a value of
approx. 195.
Example for a sensor with short circuit
AD = 1023
Example for a sensor with interruption
AD = 0001
2. Measurement:
Hydraulic system activated
Start the spreader disc on one side:
•
Spreading disc speed requirement
The AD value on the rotating side must
increase => Check whether the
pressure sensor is connected on the
correct side
•
Repeat the process for the other side