TECHNICAL INFORMATION - SERVICE
Page 2 of 4
2014-09-03_TI_AXIS-HEMC_Freigabe-Software-V3-01-00-EN(UK)
Figure 3
Switchable border and boundary spreading
The individual values for border and boundary
spreading can be entered in the fertiliser settings and
saved in the fertiliser chart.
A soft key in the main menu (figure 4) enables
switching between border and boundary spreading.
In case of operation via joystick, switching is enabled
on level 1 (figure 1).
Figure 4
The current state is displayed in the working screen
(figure 5).
Figure 5
Adaptive idle measurement
The time between 2 idle measurements is now calculated according to the type and speed of
the spreading discs, considerably reducing the number of idle measurements. In case of low oil
temperatures, an alarm message is displayed.
Agitator drive
The agitator drive is now switched on 3 seconds
after
opening the metering sliders. The drive is
started with 5 starting pulses at increased power for easier loosening of compressed fertiliser.
Target application rate input in the working
screen
In the working screen, the target application rate can
be selected directly and the new target quantity
entered in the input mask.
Figure 6