Check: Calibration of weigh cells
RAUCH Landmaschinenfabrik GmbH D-76547 Sinzheim
Customer service hotline: +49 (0)7221 985 250
E-mail: [email protected]
Page
1
of
1
29.10.2014
Chapter 640
(Figures refer to AXIS-H 30.1 EMC+W with CCI terminal)
Before the test, tare the scale to zero while
the hopper is empty.
Ideally, a known weight can be filled in for
testing. Please ensure that the weight is
positioned in the centre of the hopper.
If the spreader is loaded with a weight (e.g.
person in the hopper), the two diagnosis
bars have to be approximately equal. The
displayed weight should correspond to the
actual weight in the hopper (observe tare)
The function can also be tested in the
operating screen:
Under
kg rest
, the current weight is
displayed.
In the event of deviations between the
display and the actual weight, the
calibration needs to be repeated
=> see
chapter 3