Chapter 2: Installation
Beginning with the Dominion SX release 2.5, there are two ways of completing the initial network
installation of the Dominion SX – via Ethernet (with an installation computer), and via a serial cable with a
VT100/equivalent, e.g., a PC with HyperTerminal. Please refer to the Quick Setup Guide for Command
Line/serial cable installation instructions. This section describes the steps necessary to configure Dominion
SX for use on a local area network (LAN). All new Dominion SX units come with default network settings,
illustrated in the table below. Once units are connected to the network, these default settings will allow the
user to configure Dominion SX for normal use.
There are three separate tasks you must complete to use Dominion SX on the network: Hardware
Installation, Initial Software Configuration, and Dominion SX Deployment, usually completed in this order,
and each described in this chapter.
Hardware Installation
describes how to connect the Dominion SX unit to a computer to perform the initial
configuration of the unit. This step requires an additional computer that will be used to log into the
Dominion SX unit and configure it for the first time in the next section.
Initial Software Configuration
describes how to connect to Dominion SX in its default state and to
configure it for use in a specific network environment.
Dominion SX
Deployment describes how to install a Dominion SX unit on the network once the Initial
Software Configuration is complete.
Pre-Configuration Notes
The following list includes information that you will be required to supply to complete the configuration of
the Dominion SX. Obtain all required configuration information prior to performing the configuration steps
outlined below. If you are uncertain of any information, contact your system administrator for assistance.
Network Information:
•
Raritan Unit Name
: The name of this unit, a generic term for the Dominion SX unit. This can be 64
characters maximum, no minimum, no spaces.
•
IP address
: The IP address of the unit, as directed by your network administrator.
•
IP subnet mask
: The IP subnet mask for the unit, as directed by your network administrator.
•
IP gateway
: The IP gateway for the unit, as directed by your network administrator.
•
Port Address
: As directed by your network administrator (range is 1024-65536, this port number must
not be used by any other application, check with your network administrator if unsure, or check
IANA’s port/application listing from the Internet) default value is 51000.
•
Domain name
: Name, such as mycompany.co.jp, is required for SMTP alerts.
The following information is not required for a standalone Dominion SX installation, but is required
for installation with Raritan’s CommandCenter-Secure Gateway. Accept the default port for a
standalone installation. Port for CC discovery: 5000. Please see the CommandCenter-Secure Gateway
User Guide for additional information.
Summary of Contents for SX32
Page 2: ...This page intentionally left blank ...
Page 4: ...This page intentionally left blank ...
Page 78: ...68 DOMINION SX INSTALLATION AND OPERATIONS MANUAL ...
Page 90: ...80 DOMINION SX INSTALLATION AND OPERATIONS MANUAL ...
Page 94: ...84 DOMINION SX INSTALLATION AND OPERATIONS MANUAL ...
Page 102: ...92 DOMINION SX INSTALLATION AND OPERATIONS MANUAL ...
Page 106: ...96 DOMINION SX INSTALLATION AND OPERATIONS MANUAL ...
Page 108: ...98 DOMINION SX INSTALLATION AND OPERATIONS MANUAL ...
Page 122: ...112 DOMINION SX INSTALLATION AND OPERATIONS MANUAL ...
Page 134: ...124 DOMINION SX INSTALLATION AND OPERATIONS MANUAL ...
Page 174: ...164 DOMINION SX INSTALLATION AND OPERATIONS MANUAL ...
Page 177: ...APPENDIX J TECHNICAL FAQS 167 ...
Page 178: ...168 DOMINION SX INSTALLATION AND OPERATIONS MANUAL 255 60 2000 ...