![R&S RTA4000 User Manual Download Page 627](http://html2.mh-extra.com/html/rands/rta4000/rta4000_user-manual_3161987627.webp)
Remote control commands
R&S
®
RTA4000
627
User Manual 1335.7898.02 ─ 08
Return values:
<StartTime>
Range:
depends on sample rate, record length, and time
base
Increment: depends on the time base
Default unit: s
Usage:
Query only
BUS<b>:I2C:FRAMe<n>:BCOunt?
Returns the number of data bytes in the specified frame.
Suffix:
<b>
.
1..4
<n>
*
Selects the frame.
Return values:
<ByteCount im
Frame>
Number of words (bytes)
Example:
BUS:I2C:FRAM2:BCO?
-> 4
Usage:
Query only
BUS<b>:I2C:FRAMe<n>:BYTE<o>:ACCess?
Returns the acknowledge bit value of the specified data byte.
Suffix:
<b>
.
1..4
<n>
*
Selects the frame.
<o>
*
Selects the byte number.
Return values:
<Acknowledge>
INComplete | ACK | NACK | EITHer
Usage:
Query only
BUS<b>:I2C:FRAMe<n>:BYTE<o>:ACKStart?
Returns the start time of the acknowledge bit of the specified byte.
Suffix:
<b>
.
1..4
<n>
*
Selects the frame.
Serial bus analysis