![R&S RTA4000 User Manual Download Page 247](http://html2.mh-extra.com/html/rands/rta4000/rta4000_user-manual_3161987247.webp)
Network connections and remote operation
R&S
®
RTA4000
247
User Manual 1335.7898.02 ─ 08
If the sent command has an error, an error message is created in the background, and
you do not get any response. You can see the error messages using "Last Error Mes-
sage" and "All Error Messages"
12.3.5
Save/load
On the "Save/Load" page, you can save waveform data and instrument settings to a
file - either on the computer (local host) or on the instrument. On the computer, the
default storage directory is the download folder, but you can change the directory using
the download functions of your browser. On the instrument, the files are saved in the
internal storage.
You can also load reference waveforms and instrument settings from file to the instru-
ment ("Load from local host").
To save data to a file on the computer
1. Under "Save to local file", select the waveform or the device settings in the
"Source" list.
2. Select the file "Format".
See also:
●
Chapter 10.2.2, "Waveform file formats"
●
Chapter 7.3, "Reference waveforms"
3. For analog and digital channels, select whether you want to read out the display
memory ("Display Data") or the entire acquisition memory ("Acq. Memory").
Remote access using a web browser