7.4.4. Alarm limits
Alarms Status
Fig. 7.11: Menu Link settings – Alarms Status
Overview of alarms
All system alarms are listed on this screen. Inactive alarms are colored white with an "OK" text label.
Active alarms are colored according to the severity of the alarm (see below) with a text message de-
scribing the measured value status.
Fig. 7.12: Alarm severity scale
description
default
alarm
Temperature inside the unit (on the modem board.)
>80
Inside temperature [°C]
Lower threshold of supply voltage.
<40
Voltage min [V]
Upper threshold of supply voltage. There is the same SNMP trap
(same OID) both for Voltage min and max.
>60
Voltage max [V]
Received Signal Strength.
<−80
RSS [dBm]
Signal to Noise Ratio.
<10
SNR [dBm]
Bit Error Rate registered at the receiving end; instantaneous value.
>10e
−6
BER
77
© RACOM s.r.o. – RAy2 Microwave Link
Configuration