button is located next to the DC connector within the port
marked "P".
Disconnect the power supply from the unit. Keep the HW
button depressed while reconnecting the power. The LED
marked SYS starts to flash red after a few seconds. Keep
the HW button pressed another 5 seconds until the red status
LED stops flashing. The unit's boot up sequence continues
and Factory settings are applied.
Should the HW button be released when the status LED is
in the red flashing phase (but before the 5 s guard time), the
unit stays in Service mode. Please, leave this mode by re-
booting the unit.
To facilitate communication with the technical support you can create an archive file
with detailed information about the unit. If connection with Peer unit is active the
diagnostic information from both units are saved.
Diagnostic
package
(Local & Peer)
Saving a file with information about the unit (Local and Peer).
Create
& download file
NOTE: This task takes a few minutes to complete.
Provides Management Information Base table.
SNMP MIB
Management
Information
Base
127