Chapter 1 - Getting Started
Drive Device ID Settings
10
Drive Slot Location
Drive Device ID Settings
Located on the SES Controller card face plate are a set of switches. These switches will
configure the enclosure base Fibre address which configures the disk drives in each drive
slot with a device ID, as well as drive delay spin-up and remote spin-up options. The default
setting is all switches are set to their DOWN position.
SES Controller Card Switches
The left most three switches will configure a series of pre-determined range of device IDs.
Refer to the table below:
Disk Device ID Switch Settings
For example, if the setting for switches 1 through 3 are “Down.” the device ID addresses
for drive slots 1 - 12 would be 0 - 11 respectively.
Slot 1
Slot 4
Slot 7
Slot 10
Slot 3
Slot 6
Slot 9
Slot 12
Slot 2
Slot 5
Slot 8
Slot 11
Viewed from the front of the enclosure
SES
RS-232
A
D
0
A
D
1
1 2
Up position
Down position
3 4 5 6 7 8
A
D
2
S
P
1
S
P
2
B
D
R
D
L
Y
R
M
T
Ranges
Switch
IDs 0-11
IDs 16-27
IDs 32-43
IDs 48-59
IDs 64-75
IDs 80-91
IDs 96-107
IDs 112-123
Down
Down
Down
Down
Down
Down
Down
Down
Up
Down
Down
Up
Up
Up
Up
Down
Up
Up
Down
Up
Up
Up
Up
Up
A
D
0
A
D
1
A
D
2