Appendix A: SNMP Error Reporting
This appendix presents a list of items related to the HDFS-55X card that are available for Simple Network
Management Protocol (SNMP) information and error reporting.
Item
Description
cardType
One of nine card types: FS; UDC; UCP x 550, 551, 552, etc.
cardAlias User-assigned
name
string.
cardRev Software
version.
cardTemp
Card temperature in degrees Celsius
overTempAlarm
Card temperature greater than the threshold. User-defined setting that
defaults to 55 degrees Celsius.
refAlarm
Loss of Genlock.
vidAlarm
Loss of input video.
vidInSel
•
0=Input 1
•
1=Input 2
majorAlarm
•
0=OK
•
1=OverTemp
•
2=NoVidLock
•
3=NoRefLock
•
4=UDC-Error
minorAlarm
•
0=OK
•
2=AudioError=BadCSB or BadRxLock