Appendix A - Technical Data
130
Quincy Compressor-QSI
®
QSI 1500
Standard
Full Load Operating Pressure
psig
100
110
125
Maximum Operating Pressure
psig
115
125
140
Minimum Operating Pressure
psig
75
Maximum Ambient Operating Temperature:
Less Cabinet
°F
115
With Cabinet
°F
110
Minimum Ambient Operating Temperature
°F
32
Compressor Drive Motor
HP
300 350
Rotor Diameter
mm
321
Male Rotor Speed
rpm
1785 1790
Female Rotor Speed
rpm
1190 1193
Rotor Tip Speed
m/sec.
30.03
30.11
Inlet
Capacity
acfm
1521 1515 1504
Displacement at Operating Speed
cfm
1672.4
1677
Volumetric Efficiency
%
90.9
90.6
90.6
Aftercooling
Heat Rejection:
Fluid Cooler
BTU/min.
11611
12223
13125
Aftercooler
BTU/min.
2296
2417
2677
Aftercooler Approach (standard conditions)
°F
3-5
Maximum Allowable Static Backpressure
in./H
2
O
0.125
Fan Motor
HP
10
Fan Motor
rpm
1170
Fan Flow
cfm
26500
Water-cooled Cooling
Recommended Inlet Water Pressure
psig
40-100
Vent Fan Motor
HP
1/2
Aftercooler Approach to Cooling:
Water Temperature
°F
13-18
Water Flow less Aftercooler at: 50°F
gpm
15.9
19.7
70°F gpm
22.2
29.5
90°F gpm
39 64
Water Flow with Aftercooler at: 50°F
gpm
21.2
26
70°F gpm
29
38.2
90°F gpm
49.7
81
Compressor Fluid
Total Fluid Capacity
gallons
55
Reservoir Fluid Capacity
gallons
46.5
Fluid Flow
gpm
84
Typical Fluid Carryover
ppm
1.5-5
Normal Airend Discharge Temperature
°F
175-195
Sound (at 1 meter)
Unenclosed (AC/WC)
dB(A)
96/92
Standard Cabinet (AC/WC)
dB(A)
93/84
Low Sound Cabinet (AC)
dB(A)
85