Section VII - Compressor Fluids
106
Quincy Compressor-QSI
®
FLUID PARAMETERS
QuinSyn, QuinSyn IV & QuinSyn F
Property
Units
Test Method
Fluid Type
New Fluid
Marginal
Unacceptable
Viscosity
cSt
ASTM D-445
QuinSyn
40-48
38, 52
<38, >52 (1)
40°C
QuinSyn IV
40-48
38, 52
<38, >52 (1)
QuinSyn F
41-51
39, 56
<39, >56 (1)
Acid No.
mg KOH/gm
ASTM D-947
All
0.2
0.8-0.9
>1 (1)
TAN
ADDITIVE METALS
Barium
PPM
Plasma Emission
All
0
5-20
>20
Calcium
PPM
Plasma Emission
All
0
5-20
>20
Magnesium
PPM
Plasma Emission
All
0
5-20
>20
Molybdenum
PPM
Plasma Emission
All
0
5-20
>20
Sodium
PPM
Plasma Emission
All
0
5-20
>20
Phosphorus
PPM
Plasma Emission
All
0
5-20
>20
Zinc
PPM
Plasma Emission
All
0
100-200
>200
WEAR METALS
Silver
PPM
Plasma Emission
All
0
5-10
>10
Aluminum
PPM
Plasma Emission
All
0
5-10
>10
Chromium
PPM
Plasma Emission
All
0
5-10
>10
Copper
PPM
Plasma Emission
All
0
5-10
>10
Iron
PPM
Plasma Emission
All
0
5-10
>10
Nickel
PPM
Plasma Emission
All
0
5-10
>10
Lead
PPM
Plasma Emission
All
0
5-10
>10
Tin
PPM
Plasma Emission
All
0
5-10
>10
Titanium
PPM
Plasma Emission
All
0
5-10
>10
Vanadium
PPM
Plasma Emission
All
0
5-10
>10
OTHER
Silicon
PPM
Plasma Emission
All
0
10-15
>15
Water
PPM
Karl Fisher
All
<100
200
>200
Particle Count
Microns
Hiac Royco
All
ISO CODE X/20
Antioxidant
%
Liquid Chromatography
All
95
NOT REPORTED
(1) The fluid will be condemned based on these parameters.