Appendix A - Technical Data
128
Quincy Compressor-QSI
®
QSI 1000
Standard
Full Load Operating Pressure
psig
100
110
125
Maximum Operating Pressure
psig
115
125
140
Minimum Operating Pressure
psig
75
Maximum Ambient Operating Temperature:
Less Cabinet
°F
115
With Cabinet
°F
110
Minimum Ambient Operating Temperature
°F
32
Compressor Drive Motor
HP
200 250
Rotor Diameter
mm
321
Male Rotor Speed
rpm
1785 1790
Female Rotor Speed
rpm
1190 1193
Rotor Tip Speed
m/sec.
30.03
30.11
Inlet
Capacity
acfm
1014 1010 1003
Displacement at Operating Speed
cfm
1120 1123
Volumetric Efficiency
%
90.5
90.2
89.3
Aftercooling
Heat Rejection:
Fluid Cooler
BTU/min.
7609
7730
8310
Aftercooler
BTU/min.
1530
1610
1731
Aftercooler Approach (standard conditions)
°F
3-5
Maximum Allowable Static Backpressure
in./H
2
O
0.125
Fan Motor
HP
5
Fan Motor
rpm
1180
Fan Flow
cfm
19300
Water-cooled Cooling
Recommended Inlet Water Pressure
psig
40-100
Vent Fan Motor
HP
1/2
Aftercooler Approach to Cooling:
Water Temperature
°F
13-18
Water Flow less Aftercooler at: 50°F
gpm
10.6
13.2
70°F gpm
14.8
19.6
90°F gpm
25.6
42
Water Flow with Aftercooler at: 50°F
gpm
14.1
17.4
70°F gpm
19.1
25.5
90°F gpm
32.4
53
Compressor Fluid
Total Fluid Capacity
gallons
46
Reservoir Fluid Capacity
gallons
37.25
Fluid Flow
gpm
59.5
Typical Fluid Carryover
ppm
1.5-5
Normal Airend Discharge Temperature
°F
175-195
Sound (at 1 meter)
Unenclosed (AC/WC)
dB(A)
89/86
Standard Cabinet (AC/WC)
dB(A)
85/79
Low Sound Cabinet (AC)
dB(A)
82
Summary of Contents for QSI Series
Page 2: ......
Page 7: ...Section I General Quincy Compressor QSI 5 MODEL IDENTIFICATION...
Page 62: ...Section IV Operating Procedures 60 Quincy Compressor QSI 1 Week Timer 2 Remaining Running Time...
Page 79: ...Section IV Operating Procedures Quincy Compressor QSI 77...