Section VII - Compressor Fluids
Quincy Compressor-QSI
®
105
FLUID PARAMETERS
QuinSyn PG, QuinSyn XP & QuinSyn Plus
Property
Units
Test Method
Fluid Type
New Fluid
Marginal
Unacceptable
Viscosity
cSt
ASTM D-445
QuinSyn PG
45-55
41,61
<41, >61 (1)
40°C
QuinSyn XP
58-75
50, 85
<50, >85 (1)
QuinSyn Plus
42-51
38, 56
<38, >56 (1)
Acid No.
mg KOH/gm
ASTM D-947
QuinSyn PG
<0.2
0.7-0.9
>1 (1)
TAN
QuinSyn XP
<0.2
3-4
>4 (1)
QuinSyn Plus
<0.2
1.7-1.9
>2.0 (1)
ADDITIVE METALS
Barium
PPM
Plasma Emission
QuinSyn PG
375-550
150
<10 (1)
QuinSyn XP
0
5-20
>20
QuinSyn Plus
0
5-20
>20
Calcium
PPM
Plasma Emission
All
0
5-20
>20
Magnesium
PPM
Plasma Emission
All
0
5-20
>20
Molybdenum
PPM
Plasma Emission
All
0
5-20
>20
Sodium
PPM
Plasma Emission
QuinSyn PG
0
40-50
>100
QuinSyn XP
0
40-50
>100
QuinSyn Plus
0
5-20
>20
Phosphorus
PPM
Plasma Emission
QuinSyn PG
0
5-20
>20
QuinSynXP <50 5-20 0
QuinSyn Plus
0
5-20
>20
Zinc
PPM
Plasma Emission
All
0
100-200
>200
WEAR METALS
Silver
PPM
Plasma Emission
All
0
5-10
>10
Aluminum
PPM
Plasma Emission
All
0
5-10
>10
Chromium
PPM
Plasma Emission
All
0
5-10
>10
Copper
PPM
Plasma Emission
All
0
5-10
>10
Iron
PPM
Plasma Emission
All
0
5-10
>10
Nickel
PPM
Plasma Emission
All
0
5-10
>10
Lead
PPM
Plasma Emission
All
0
5-10
>10
Tin
PPM
Plasma Emission
All
0
5-10
>10
Titanium
PPM
Plasma Emission
All
0
5-10
>10
Vanadium
PPM
Plasma Emission
All
0
5-10
>10
OTHER
Silicon
PPM
Plasma Emission
All
0
10-15
>15
Water
PPM
Karl Fisher
QuinSyn PG
<2000
NOT REPORTED
QuinSynXP
<800
NOT REPORTED
QuinSyn Plus
<800
NOT REPORTED
Antioxidant
%
HPCL
All
95% min.
NOT REPORTED
(1) The fluid will be condemned based on these parameters.
Summary of Contents for QSI Series
Page 2: ......
Page 7: ...Section I General Quincy Compressor QSI 5 MODEL IDENTIFICATION...
Page 62: ...Section IV Operating Procedures 60 Quincy Compressor QSI 1 Week Timer 2 Remaining Running Time...
Page 79: ...Section IV Operating Procedures Quincy Compressor QSI 77...