Procedure
Step
Action
-
Press stop button (11). Automatic operation LED (3) goes out and the compressor stops after 30
seconds of unloaded operation.
-
To stop the compressor in the event of an emergency,
press emergency stop button. Alarm
LED flashes (5).
•
Remedy the problem cause and unlock the button by pulling it out.
•
Navigate to the Stop icon on the display by means of the navigation keys (12) and press the
Select key.
Press reset.
Do not use emergency stop button for normal stopping!
-
Close the air outlet valve (AV).
-
Press the test button on the top of the electronic water drain(s) until the air system between the
air system receiver and the outlet valve is fully depressurised. See section
Switch off the voltage.
-
If available, open the condensate drain valve of the compressor (Dm) to drain the water trap
completely.
5.7
Taking out of operation
Procedure
Step
Action
-
Stop the compressor and close the air outlet valve.
-
Switch off the voltage and disconnect the compressor from the mains.
-
If available, open the condensate drain valve(s) (Dm).
-
Shut off and depressurise the part of the air net which is connected to the outlet valve. Disconnect
the compressor air outlet pipe from the air net.
-
Drain the oil.
-
Drain the condensate circuit and disconnect the condensate piping from the condensate net.
Instruction book
70
2920 7101 21