Condition
Fault
Remedy
Compressor air output or pressure
below normal
Air consumption exceeds air
delivery of compressor
Check equipment connected
Choked air filter element
Replace filter element
Solenoid valve malfunctioning
Replace valve
Leak in control air flexibles
Replace leaking flexibles
Inlet valve does not fully open
Have valve checked
Oil separator clogged
Have element replaced
Air leakage
Have leaks repaired
Safety valve leaking
Have valve replaced
Compressor element out of order Consult your supplier
-
Condition
Fault
Remedy
Excessive oil consumption; oil
carry-over through discharge line
Oil level too high
Check for overfilling. Release
pressure and drain oil to
correct level
Incorrect oil causing foam
Change to correct oil
Oil separator defective
Have element checked.
Replace if necessary.
Scavenge line clogged
Check and remedy
-
Condition
Fault
Remedy
Excessive oil flow through air inlet
filter after stopping compressor
Check valve leaking or oil stop
valve jammed
Replace defective parts.
Replace air filter element
-
Condition
Fault
Remedy
Safety valve blows after loading
Inlet valve malfunctioning
Have valve checked
Minimum pressure valve
malfunctioning
Have valve checked
Safety valve out of order
Have valve replaced
Compressor element out of order Consult your supplier
Oil separator element clogged
Have element replaced
-
Condition
Fault
Remedy
Compressor element outlet
temperature or delivery air
temperature above normal
Oil level too low
Check and correct
On air-cooled compressors,
insufficient cooling air or cooling
air temperature too high
Check for cooling air restriction
or improve ventilation of the
compressor room. Avoid
circulation of cooling air. If
installed, check capacity of
compressor room fan
Oil cooler clogged
Clean cooler
Instruction book
2920 7101 21
81