Instruction Book
114
9828 0934 73
ES 310
– ES 410 – ES 510 Air-cooled 60 Hz
Performance data
Unit
Pressure dewpoint air outlet
•
Ambient air temperature 38 °C Compressed air inlet temperature
38 °C
°C
4
4
3
•
Ambient air temperature 100 °F Compressed air inlet
temperature 100 °F
°F
39.2
39.2
37.4
•
Ambient air temperature 25 °C Compressed air inlet temperature
35 °C
°C
2
3
3
•
Ambient air temperature 77 °F Compressed air inlet temperature
95 °F
°F
35.6
37.4
37.4
•
Ambient air temperature 30 °C Compressed air inlet temperature
40 °C
°C
3
4
4
•
Ambient air temperature 86 °F Compressed air inlet temperature
104 °F
°F
37.4
39.2
39.2
•
Ambient air temperature 35 °C Compressed air inlet temperature
45 °C
°C
6
4
5
•
Ambient air temperature 95 °F Compressed air inlet temperature
113 °F
°F
42.8
39.2
41.0
•
Ambient air temperature 40 °C Compressed air inlet temperature
50 °C
°C
13
11
6
•
Ambient air temperature 104 °F Compressed air inlet
temperature 122 °F
°F
55.4
51.8
42.8
•
Ambient air temperature 46 °C Compressed air inlet temperature
56 °C
°C
19
22
13
•
Ambient air temperature 115 °F Compressed air inlet
temperature 133 °F
°F
66.2
71.6
55.4
Total electrical power input
•
Ambient air temperature 38 °C Compressed air inlet temperature
38 °C
kW
4.6
6.1
9.1
•
Ambient air temperature 100 °F Compressed air inlet
temperature 100 °F
hp
6.2
8.2
12.2
•
Ambient air temperature 25 °C Compressed air inlet temperature
35 °C
kW
3.6
6.1
7.9
•
Ambient air temperature 77 °F Compressed air inlet temperature
95 °F
hp
4.8
8.2
10.6
•
Ambient air temperature 30 °C Compressed air inlet temperature
40 °C
kW
4.1
6.1
8.1
•
Ambient air temperature 86 °F Compressed air inlet temperature
104 °F
hp
5.5
8.2
10.9
•
Ambient air temperature 35 °C Compressed air inlet temperature
45 °C
kW
4.7
6.1
8.6
•
Ambient air temperature 95 °F Compressed air inlet temperature
113 °F
hp
6.3
8.2
11.5
•
Ambient air temperature 40 °C Compressed air inlet temperature
50 °C
kW
5.3
6.7
10.1
QED650
ES 310
QED850
ES 410
QED1050
ES