Aeration Goals 

Warranty

Product Damaged in Delivery

System Materials List

Safety

Cabinet & Compressor

AirStation

TM

 Installation

AirStation

TM 

Balancing

2

2

2

3

4

5

6

6

6

7

8

9

10

11

12

12

System Start-up 

Installation Steps

Maintenance 

Winter Operations

Compressor Diagram

Troubleshooting Guide 

Maintenance Log 

Parts List

220V-240V Aeration

Owner’s Manual

Outside the US and Canada

1.844.432.4303  

vertexaquaticsolutions.com | [email protected]

Hours of Operation: M-F, 8am-5pm EST

© Vertex Aquatic Solutions

Summary of Contents for Vertex Aquatic Solutions AirStation

Page 1: ...3 4 5 6 6 6 7 8 9 10 11 12 12 System Start up Installation Steps Maintenance Winter Operations Compressor Diagram Troubleshooting Guide Maintenance Log Parts List 220V 240V Aeration Owner s Manual Outside the US and Canada 1 844 432 4303 vertexaquaticsolutions com info vertexaquaticsolutions com Hours of Operation M F 8am 5pm EST Vertex Aquatic Solutions ...

Page 2: ...in 15 days of delivery Do not move damaged goods from original point of delivery Retain all original packing and containers for inspection File a FULL VALUE REPLACEMENT claim against the transportation company SYSTEM MATERIALS LIST Verify that you received the following QuietAir Compressor Cabinet with Poly Plastic Mounting Pad the cabinet houses the compressor s inlet filter muffler assembly air ...

Page 3: ...t sand or grit entering the cabinet will damage the motor and compressor Installer l armoire système dans une zone très sale excès de matières en suspension dans l air sable gravier dans endommagera le moteur et le compresseur Call your dealer or Vertex Aquatic Solutions for help resolving installation problems Appelez votre revendeur ou l eau Caractéristiques de Vertex pour des problèmes aide à l...

Page 4: ...cadrés ne sont pas à jouer avec l appareil ELECTRIC INSTALLATION INSTRUCTIONS Contract a licensed electrical contractor The unit is built as a cord connected product only The unit is rated for 230V Single Phase The unit does not provide a GFCI receptacle The complete circuit must be protected by a 2 pole 20 amp GFCI breaker rated for 230V Unit must be plugged into an electrical approved receptacle...

Page 5: ...ted Turn system off at disconnect switch and call Vertex to correct any problems If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard Before performing any maintenance and troubleshooting disconnect the electricity by turning off disconnect switch or unplug the unit When in or around water wear a Coast Gua...

Page 6: ...d simply take the cabinet and plastic mounting pad and place them on top of the cement pad Drill four holes one in each corner of the plastic pad using a masonry drill bit Insert a wedge anchor through the plastic pad and into the cement Using the nut and washer supplied with the anchor kit purchased separately fasten the plastic pad to the cement pad you made Contract a licensed electrical contra...

Page 7: ...the water 6 Holding both ends of the rope in your hand lower the diffuser assembly into the water Once unit is on lake bottom release one end of the rope and pull rope into the boat 7 Head out with the other end of the tubing Make sure the propeller and tubing do not get tangled up 4 At the drop site connect the tubing to the barbed fitting Use PVC cement and let dry recommended method or 5a Conne...

Page 8: ...ssible pressure The lower the system pressure the higher the total air flow WARNING ATTENTION If the system has been installed in an established pond and you are attempting to balance the AirStations during the first day of operation make certain that this procedure takes as little time as possible Si vous installez un système dans un ancien étang et que vous essayez d équilibrer les AirStation lo...

Page 9: ...et or other electrical components need service Ventilateur du compresseur de sortie ou d autres composants électriques besoin de service If the cabinet is producing unusual noises or odors Si le coffret est produisant des bruits ou des odeurs inhabituels Vertex aeration systems are designed for low maintenance and typically only require minimal scheduled maintenance Periodic cleaning and or replac...

Page 10: ...ooling for the cabinet components If the cooling fans fail cabinet temperatures will drastically increase and damage the compressor system For systems that run continuously we recommend replacing the cooling fans every two or three years during compressor maintenance DISK FLEX CLEANING PROCEDURES Routine maintenance of the AirStation disks is recommended once per year This procedure is known as di...

Page 11: ...sera de grandes zones d eau libre de rester sur les sites ébullition L épaisseur de la glace autour de ces zones ouvertes seront beaucoup plus mince que la glace sur le reste du lac Blessure ou décès peuvent résulter de la chute à travers la glace Vertex recommande fortement que ce danger de glace mince autour de la zone ébullition être clairement affichés à intervalles fréquents Propriétaire assu...

Page 12: ... to Ground Terminal Terminals 1 L1 and 3 L2 Supply Cabinet Components Disconnect Switch Wiring Schematic A AIRSTATION VALVES B CABINET FAN AND GUARD C CAPACITOR D CHECK VALVE E COMPRESSOR FAN GUARD F INTAKE FILTER MUFFLER G PRESSURE RELEASE VALVE H SOLENOID VALVE I PRESSURE GAUGE J DISCONNECT SWITCH 12 Vertex Aquatic Solutions QA1 Cabinet B C E F G I J QA2 Cabinet A B C D E F G H I J ...

Page 13: ...PRESSURE RELEASE VALVE H SOLENOID VALVE I PRESSURE GAUGE J DISCONNECT SWITCH D J A B C D E F G H I J LargeLake Cabinets A AIRSTATION VALVES B DUAL RECEPTACLE BOXES C PRESSURE GAUGE D CHECK VALVE E COMPRESSOR FAN GUARD F INTAKE FILTER MUFFLER G SOLENOID VALVE H SAFETY POP OFF VALVE I CABINET FRAME J COOLING FANS K DISCONNECT SWITCH D A C E F G H J K ...

Page 14: ...are wide open Improper balancing of AirStations See AirStation Balancing section for instructions to balance AirStations Valves in cabinet are balanced and no leaks are evident Compressor is losing compression and needs piston rebuild kit Contact Vertex or dealer with compressor specifications for rebuild kit Keep muffler filter clean Large rolling bubbles instead of fine bubbles at surface above ...

Page 15: ... sévère ou d électrocution toujours couper l alimentation au panneau de service avant de travailler avec l électricité Date Maintenance Performed Date Maintenance Performed Date Maintenance Performed Date Maintenance Performed Date Maintenance Performed Date Maintenance Performed Date Maintenance Performed Date Maintenance Performed Date Maintenance Performed 15 Owner s Manual ...

Page 16: ...1 844 432 4303 vertexaquaticsolutions com info vertexaquaticsolutions com Hours of Operation M F 8am 5pm EST Vertex Aquatic Solutions ...