Instruction Book
9828 0934 73
125
ES 310 VSD
– ES 410 VSD – ES 510 VSD Air-cooled 60 Hz
Performance data
Unit
Pressure dewpoint air outlet
Economy mode
•
Ambient air temperature 25 °C
Compressed air inlet temperature 35 °C
°C
5
5
5
•
Ambient air temperature 77 °F
Compressed air inlet temperature 95 °F
°F
41
41
41
•
Ambient air temperature 40 °C
Compressed air inlet temperature 50 °C
°C
20
20
20
•
Ambient air temperature 104 °F
Compressed air inlet temperature 122 °F
°F
68
68
68
Maximum saving mode
•
Ambient air temperature 25 °C
Compressed air inlet temperature 35 °C
°C
10
10
10
•
Ambient air temperature 77 °F
Compressed air inlet temperature 95 °F
°F
50
50
50
•
Ambient air temperature 40 °C
Compressed air inlet temperature 50 °C
°C
25
25
25
•
Ambient air temperature 104 °F
Compressed air inlet temperature 122 °F
°F
77.0
77.0
77.0
Lowest dewpoint mode
•
Ambient air temperature 25 °C
Compressed air inlet temperature 35 °C
°C
3
3
3
•
Ambient air temperature 77 °F
Compressed air inlet temperature 95 °F
°F
37.4
37.4
37.4
•
Ambient air temperature 38 °C
Compressed air inlet temperature 38 °C
°C
4
4
4
•
Ambient air temperature 100 °F
Compressed air inlet temperature 100 °F
°F
39.2
39.2
39.2
•
Ambient air temperature 40 °C
Compressed air inlet temperature 50 °C
°C
17
17
20
•
Ambient air temperature 104 °F
Compressed air inlet temperature 122 °F
°F
62.6
62.6
68
Total electrical power input
Economy mode
•
Ambient air temperature 25 °C
Compressed air inlet temperature 35 °C
kW
2.37
3.06
3.61
•
Ambient air temperature 77 °F
Compressed air inlet temperature 95 °F
hp
3.18
4.10
4.84
•
Ambient air temperature 40 °C
Compressed air inlet temperature 50 °C
kW
4.43
5.29
6.91
•
Ambient air temperature 104 °F
Compressed air inlet temperature 122 °F
hp
5.94
7.09
9.27
Maximum saving mode
•
Ambient air temperature 25 °C
Compressed air inlet temperature 35 °C
kW
1.91
2.25
2.85
•
Ambient air temperature 77 °F
Compressed air inlet temperature 95 °F
hp
2.56
3.02
3.82
•
Ambient air temperature 40 °C
kW
3.09
3.45
4.77
QPVS650
QPVS850
QPVS1050