Instruction Book
118
9828 0934 73
Unit
At ambient temperature of:
°F
100
77
86
95
104
At ambient temperature of:
°C
38
25
30
35
40
Volume flow at dryer inlet
under nominal conditions
cfm
869
869
869
869
869
Volume flow at dryer inlet
under nominal conditions
l/s
410
410
410
410
410
Pressure dew-point
˚F
37
37
41
52
66
Pressure dew-point
˚C
3
3
5
11
19
Total power consumption
hp
4.2
4.2
4.2
4.2
4.3
Total power consumption
kW
3.1
3.1
3.1
3.1
3.2
Cooling water flow (approx.)
*)
cfm
0.4
0.6
0.6
0.6
0.6
Cooling water flow (approx.)
*)
l/s
0.2
0.3
0.3
0.3
0.3
Heat dissipated by
cooling water flow
(approx.)
Btu/hr
37600
37600
41000
47800
51200
Heat dissipated by
cooling water flow
(approx.)
kW
11
11
12
14
15
*)
Cooling water flow at
25 ˚C (77 ˚F) water inlet (approx.) and a temperature difference of 10 ˚C (18 ˚F).
Performance data with cooling water inlet of 40 °C (104 °F)