12
External
view
-
two
push-open
sliding
doors
In entrances with two push-open
sliding doors (fixed laterally or to the
wall), the automation must be installed
externally, to allow the doors to be
pushed open in any sliding position. It
is therefore necessary to provide STOP
photocells if the doors are pushed
open.
If beyond the sliding doors there are
also semi-fixed sides that can be
pushed open, instead of the STOP
photocells it is sufficient to install two
electrical contacts that open the circuit,
blocking the sliding doors, in case of
opening of the semi-fixed doors
(which will happen each time the
sliding doors are pushed open).
12
- INSTALLATION AND ADJUSTMENT OF DOORS
It is advisable to assemble the doors in the workshop and then
install the adaptor profile as well. It is not advisable to install
it at the worksite.
It is advisable to install a reinforcement on the crosspiece of
the door. Do not use self-threading screws to attach the
adaptor, but rather M6 metric screws, or insert directly in the
aluminium profile threaded press-in inserts about every 30 cm.
The head of the screw must have a maximum height of 6 mm.
The distances listed below must be complied with for the fastening
of the carriages, different sizes of automations for one or two doors.
STOP photocells
Position of carriages for double door
Position of carriages for single doors – opening to left
Position of carriages for single doors – opening to right
Summary of Contents for WINNY LIGHT