11 - ELECTRICAL SETUP
Electrical setup - Internal view
1.
Function selector (shielded cable 8 x Ø 0.22 mm)
2.
Possible push button control (cable 2 x Ø 0.22mm)
3.
Control by key or external code (cable 4 x Ø 0.22mm)
4.
Power supply cable(Neutral, Line, Earth) (cable 3 x Ø 1.5 mm)
5.
Safety photocells (cable provided to be run all the way into the beam)
6.
Impulse parts (radar) (cable 4 x Ø 0.22 mm)
Looking at the box of the automation, all cables must arrive at the right side with 3 m. of excess
cable.
N.B.
If you use a single pair of photocells, the
height of fastening above the ground is
50 cm.
If you use a double pair of photocells, the
height of fastening above the ground is 20
and
100
cm.
External view - double pair of photocells