Set termination to
Automatic
•
Go to
Advanced configuration
♥
Set “Reset SCSI bus at IC Initialization” to
Disabled
♥
Press “Esc”, and “Esc”, and “Save changes”.
•
Press “Esc”, and “Esc”, and exit utility.
Step 4
Configure the SCSI ID's for the LVD/HVD adapters (connected to the library) on the cluster
nodes.
•
Enter the LVD/HVD SCSI BIOS Setup on Node1 for the adapter connected to the library:
•
Set
termination
mode to
automatic
•
Set
Reset SCSI Bus
parameter to
disabled
•
Set the SCSI ID of this board to 5
•
Enter the LVD/HVD SCSI BIOS Setup on Node2 for the adapter connected to the library.
•
Set
termination
mode to
automatic
•
Set
Reset SCSI Bus
parameter to
disabled
•
Set the SCSI ID of this board to 6
Step 5
Log on. Update drivers (Adaptec, QLA, etc.) as described in
Updating Drivers
on page 110.
Step 6
Shutdown Node1.
Step 7
Repeat steps 2 - 5 using Node2 instead of Node1.
Step 8
Initialize LUN 0.
To initialize LUN 0, go to
Main Menu > Change Configuration > Password
In the
Password
field, type:
1 2 3 4
then
Raid Config > Initialize LU
In the
Initialize LU
field, type:
Yes
On the keyboard, press 0
Note
Both adapters must have different SCSI IDs.
Adapter IDs must not overlap with the single aisle LIBRARY SCSI ID.
Adapter IDs must not overlap with the either of the LIBRARY SCSI IDs for the dual-aisle
libraries.
Any number could be used as SCSI IDs as long as it follows the rules above.
Note
The RAID initialization takes a minimum of 3 hours.
Summary of Contents for SDLC 2.7
Page 1: ...InstallationGuide Scalar DistributedLibraryController 2 7...
Page 6: ...vi Table of Contents...
Page 14: ...8 System Description...
Page 56: ...50 Setting Up the Scalar DLC...
Page 76: ...70 Installing the Scalar DLC...
Page 82: ...76 DAS Client...
Page 120: ...114 Upgrade Remove Repair...
Page 130: ...124 SCSI FC Target Drivers...