Installation Guide
111
•
For NodeB do
Setting Up the RAID
on page 28 from
Step 4
on page 29.
•
Start up NodeA. For NodeB do
Configuring Cluster Service
on page 29 from
Step 4
on page 30
(on Windows 2000) or from
Step 3
on page 31 (on Windows 2003).
•
On NodeA take Scalar DLC offline. On NodeB do
Installing Scalar DLC Software
on page 32,
steps 3, 5 - 7.
•
(optional) On NodeB do
Building Client Connections
on page 139.
•
Take Scalar DLC online and proceed.
Scalar DLC chassis bad
Step 1
Power off failed node.
Step 2
Disconnect all cabling.
Step 3
Move all disk, SCSI cards and fibre cards to the new node.
Step 4
Reconnect cabling and power on new node.
One disk fails in the external RAID
Step 1
Remove the cover and unlock the disk.
Step 2
Remove failed disk and insert new disk
Step 3
Reconstruction will begin. Approximate reconstruction time is 6 hours
Step 4
Hit the up arrow until buzzer stop shows on display.
Step 5
Hit the yellow button twice
Two disk fail in the external RAID
Step 1
Replace both failed disks.
Step 2
Initialize the RAID. Initialization takes approximately 2 hours.
Step 3
Reinstall the Scalar DLC from scratch
Step 4
Restore database from the back up.
RAID controller fails
Step 1
Power down RAID
Step 2
Disconnect all cabling from RAID
Step 3
Remove all disk from failed RAID
Step 4
Insert disk into new RAID chassis
Step 5
Reconnect cabling and power on
Step 6
Run the Installation for ADTX RAID procedure
Summary of Contents for SDLC 2.7
Page 1: ...InstallationGuide Scalar DistributedLibraryController 2 7...
Page 6: ...vi Table of Contents...
Page 14: ...8 System Description...
Page 56: ...50 Setting Up the Scalar DLC...
Page 76: ...70 Installing the Scalar DLC...
Page 82: ...76 DAS Client...
Page 120: ...114 Upgrade Remove Repair...
Page 130: ...124 SCSI FC Target Drivers...